  4. HDR Images for Glare Evaluation: Comparison Between DSLR Cameras, an Absolute Calibrated Luminance Camera and a Spot Luminance Meter
 
conference paper

HDR Images for Glare Evaluation: Comparison Between DSLR Cameras, an Absolute Calibrated Luminance Camera and a Spot Luminance Meter

Hansen, Peter  
•
Wienold, Jan  
•
Andersen, Marilyne  
2017
Proceedings of the Conference on "Smarter Lighting for Better Life" at the CIE Midterm Meeting 2017
“Smarter Lighting for Better Life” at the CIE Midterm Meeting 2017

User calibrated digital single-lens reflex (DSLR) cameras are being used in visual comfort and especially for glare evaluations as affordable alternatives to high-end luminance cameras calibrated by the manufacturer itself. While the typical way for a user calibrated camera is the application of an automatic calibration algorithm, manufacturers, on the other hand, tend to rely on a calibration process for their cameras based on measurements performed for each exposure setting (absolute calibration). This paper investigates the accuracy of luminance maps derived from HDR images captured with auto-calibrated DSLR cameras. More specifically, the aim of this study is to compare the luminance values obtained with an auto-calibrated DSLR camera for different light scenarios on one hand to a commercially available camera (that benefited from an absolute calibration) and on the other hand to a handheld luminance meter, considered as the reference. It was found that there are only small differences when luminance values estimated with auto-calibrated DSLR cameras are compared with those obtained for the commercially calibrated camera for low to mid-range luminance values (50 – 5000 cd/m 2 ). However, for higher luminance values (>5000 cd/m 2 ), HDR images from the auto-calibrated camera show differences of up to 20 % when compared to the manufacturer calibrated camera, which could be problematic for glare investigations. More studies specifically focusing on high luminances are thus needed, so as to determine more conclusively whether certain limitations should apply to the use of automatically calibrated DSLR cameras for glare evaluations.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

Camera_1.jpg

Access type

openaccess

Size

57.94 KB

Format

JPEG

Checksum (MD5)

cd8a02d7c89d0d95d85b62682a20c6e3

Loading...
Thumbnail Image
Name

HDR images for glare evaluation Comparison between dslr cameras, an absolute calibrated luminance camera and a spot luminance meter.pdf

Access type

openaccess

Size

558.73 KB

Format

Adobe PDF

Checksum (MD5)

4f68213a78a2fc40275c18ba92d618d5

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés