  4. HDR Images for Glare Evaluation: Comparison Between DSLR Cameras, an Absolute Calibrated Luminance Camera and a Spot Luminance Meter
 
conference paper

HDR Images for Glare Evaluation: Comparison Between DSLR Cameras, an Absolute Calibrated Luminance Camera and a Spot Luminance Meter

Hansen, Peter  
•
Wienold, Jan  
•
Andersen, Marilyne  
2017
Proceedings of the Conference on "Smarter Lighting for Better Life" at the CIE Midterm Meeting 2017
“Smarter Lighting for Better Life” at the CIE Midterm Meeting 2017

User calibrated digital single-lens reflex (DSLR) cameras are being used in visual comfort and especially for glare evaluations as affordable alternatives to high-end luminance cameras calibrated by the manufacturer itself. While the typical way for a user calibrated camera is the application of an automatic calibration algorithm, manufacturers, on the other hand, tend to rely on a calibration process for their cameras based on measurements performed for each exposure setting (absolute calibration). This paper investigates the accuracy of luminance maps derived from HDR images captured with auto-calibrated DSLR cameras. More specifically, the aim of this study is to compare the luminance values obtained with an auto-calibrated DSLR camera for different light scenarios on one hand to a commercially available camera (that benefited from an absolute calibration) and on the other hand to a handheld luminance meter, considered as the reference. It was found that there are only small differences when luminance values estimated with auto-calibrated DSLR cameras are compared with those obtained for the commercially calibrated camera for low to mid-range luminance values (50 – 5000 cd/m 2 ). However, for higher luminance values (>5000 cd/m 2 ), HDR images from the auto-calibrated camera show differences of up to 20 % when compared to the manufacturer calibrated camera, which could be problematic for glare investigations. More studies specifically focusing on high luminances are thus needed, so as to determine more conclusively whether certain limitations should apply to the use of automatically calibrated DSLR cameras for glare evaluations.

  • Files
  • Details
  • Metrics
Type
conference paper
Author(s)
Hansen, Peter  
Wienold, Jan  
Andersen, Marilyne  
Date Issued

2017

Publisher

CIE - International Commission on Illumination

Published in
Proceedings of the Conference on "Smarter Lighting for Better Life" at the CIE Midterm Meeting 2017
Start page

553

End page

563

Subjects

Photometry

•

HDR imaging

•

Camera calibration

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LIPID  
Event nameEvent placeEvent date
“Smarter Lighting for Better Life” at the CIE Midterm Meeting 2017

Jeju, South Korea

October 23 - 25, 2017

Available on Infoscience
December 27, 2017
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/143558
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés