Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Determinants of pulse pressure
 
research article

Determinants of pulse pressure

Stergiopulos, N.  
•
Westerhof, N.
1998
Hypertension

We have searched to define the major arterial parameters that determine aortic systolic (Ps) and diastolic (Pd) pressure in the dog. Measured aortic flows were used as input to the 2-element windkessel model of the arterial system, with peripheral resistance calculated as mean pressure divided by mean flow and total arterial compliance calculated from the decay time in diastole. The windkessel model yielded an aortic pressure wave from which we obtained the predicted systolic (Ps,wk) and diastolic (Pd,wk) pressures. These predicted pressures were compared with the measured systolic and diastolic pressures. The measurements and calculations were performed for 7 dogs under control conditions during aortic occlusion at 4 locations (the trifurcation, between the trifurcation and diaphragm, the diaphragm, and the proximal descending thoracic aorta) and during occlusion of both carotid arteries. Under all conditions studied, the predicted systolic and diastolic pressures matched the experimental ones very well: Ps,wk=(1.000+/-0.0055) Ps with r=0.958 and Pd,wk=(1.024+/-0.0035) Pd with r=0.995. Linear regression for pulse pressure (PP) resulted in PPwk=(0.99+/-0.016) PP with r=0.911. We found the accuracy of prediction equally good under control conditions and in the presence of aortic or carotid artery occlusion. Multiple regression between pulse pressure and arterial resistance and total arterial compliance yielded a poor regression constant (R2=0.19), suggesting that the 2 arterial parameters alone cannot explain pulse pressure and that flow is an important determinant as well. We conclude that for a given ejection pattern (aortic flow), 2 arterial parameters, total arterial resistance and total arterial compliance, are sufficient to accurately describe systolic and diastolic aortic pressure.

  • Details
  • Metrics
Type
research article
DOI
10.1161/01.HYP.32.3.556
PubMed ID

9740625

Author(s)
Stergiopulos, N.  
Westerhof, N.
Date Issued

1998

Published in
Hypertension
Volume

32

Issue

3

Start page

556

End page

559

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LHTC  
LCB  
Available on Infoscience
December 16, 2010
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/62294
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés