Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Total arterial compliance, estimated by a novel method, is better related to left ventricular mass compared to aortic pulse wave velocity: The SAFAR study
 
research article

Total arterial compliance, estimated by a novel method, is better related to left ventricular mass compared to aortic pulse wave velocity: The SAFAR study

Papaioannou, Theodore G.
•
Protogerou, Athanase D.
•
Argyris, Antonis
Show more
2017
Clinical And Experimental Hypertension

Aim: The investigation of the association between total arterial compliance (C-T)-estimated by a novel technique-with left ventricular mass (LVM) and hypertrophy (LVH). Our hypothesis was that C-T may be better related to LVM compared to the gold-standard regional aortic stiffness. Within the frame of the ongoing cross-sectional study "SAFAR," 226 subjects with established hypertension or with suspected hypertension underwent blood pressure (BP) assessment, carotid-to-femoral pulse wave velocity (cf-PWV), and echocardiographic measurement of LVM. LVM index (LVMI) was calculated by the ratio of LVM to body surface area. C-T was estimated by a previously proposed and validated formula: C-T = 36.7 /cf-PWV2 [ml/mmHg]. LVMI was related to age (r = 0.207, p = 0.002), systolic BP (r = 0.248, p < 0.001), diastolic BP (r = 0.139, p = 0.04), mean BP (r = 0.212, p = 0.002), pulse pressure (r = 0.212, p = 0.002), heart rate (r = -0.172, p = 0.011), cf-PWV (r = 0.268, p < 0.001), and C-T (r = -0.317, p < 0.001). The highest correlation was observed for CT that was significantly stronger than the respective correlation of cf-PWV (p < 0.001). In multivariate analysis, C-T was a stronger determinant, compared to cf-PWV, of LVMI and LVH. It remains to be further explored whether C-T has also a superior prognostic value beyond and above local or regional (segmental) estimates of pulse wave velocity.

  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés