Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. On the preparation and mechanical testing of nano to micron-scale specimens
 
Loading...
Thumbnail Image
research article

On the preparation and mechanical testing of nano to micron-scale specimens

Borasi, Luciano
•
Slagter, Alejandra
•
Mortensen, Andreas  
Show more
January 15, 2025
Acta Materialia

Over the past two decades, means allowing to probe experimentally the mechanical behavior of materials specimens only a few micrometers or less in diameter have multiplied, largely owing to the widespread adoption and versatility of focused ion beam (FIB) milling for the preparation of small-scale test specimens. Despite its remarkable capabilities, the ion bombardment that is employed during FIB milling operations does not leave machined surfaces unscathed: it may induce a series of alterations in the near-surface microstructure of materials, which vary in severity depending on the material being milled, or milling parameters, or the type of ion used. These alterations in turn can strongly influence the local behavior, and as a result measured mechanical properties, of the milled material. In the first part of this manuscript, we review the different forms that FIB-induced microstructural alterations can take and their influence on small-scale mechanical test results. In the second part, we present alternative strategies that have been used to circumvent the issue. These include the use of entirely different small-scale sample fabrication processes, as well as approaches that do use FIB-milling but put effort in the test design to minimize or avoid the formation of FIB-induced defects in regions where micromechanical test data are collected. The advent of such methods can enhance our understanding of FIB-induced defects on the mechanical behavior of microsamples by comparing the results with those from ion-milled samples. This, in turn, should improve our ability to interpret test data when FIB-milling is the only method available for microsample production.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1016/j.actamat.2024.120394
Scopus ID

2-s2.0-85205251836

Author(s)
Borasi, Luciano
•
Slagter, Alejandra
•
Mortensen, Andreas  
•
Kirchlechner, Christoph
Date Issued

2025-01-15

Published in
Acta Materialia
Volume

283

Article Number

120394

Subjects

Ion beam processing

•

Ion irradiation

•

Mechanical properties

•

Micron scale

•

Size effect

Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LMM  
FunderFunding(s)Grant NumberGrant URL

CEMES-CNRS in Toulouse

Institute for Applied Materials

Karlsruhe Institute of Technology

Show more
Available on Infoscience
January 25, 2025
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/243999
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés