Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Conferences, Workshops, Symposiums, and Seminars
  4. Design of a Flexure Based Low Frequency Foucault Pendulum
 
conference paper

Design of a Flexure Based Low Frequency Foucault Pendulum

Flückiger, Patrick Robert  
•
Vardi, Ilan  
•
Henein, Simon  
August 16, 2020
Proceedings of the ASME 2020 International Design Engineering Technical Conferences & Computers and Information in Engineering Conference IDETC/CIE 2020
ASME 2020 International Design Engineering Technical Conferences & Computers and Information in Engineering Conference IDETC/CIE 2020

The Foucault pendulum is a well-known mechanism used to demonstrate the rotation of the Earth. It consists in a pendulum launched on linear orbits and, following Mach’s Principle, this line of oscillation will remain fixed with respect to absolute space but appear to slowly precess for a terrestrial observer due to the turning of the Earth. The theoretical proof of this phenomenon uses the fact that, to first approximation, the Foucault pendulum is a harmonic isotropic two degree of freedom (2-DOF) oscillator. Our interest in this mechanism follows from our research on flexure-based implementations of 2-DOF oscillators for their application as time bases for mechanical timekeeping. The concept of the Foucault pendulum therefore applies directly to 2-DOF flexure based harmonic oscillators. In the Foucault pendulum experiment, the rotation of the Earth is not the only source of precession. The unavoidable defects in the isotropy of the pendulum along with its well-known intrinsic isochronism defect induce additional precession which can easily mask the precession due to Earth rotation. These effects become more prominent as the frequency increases, that is, when the length of the pendulum decreases. For this reason, short Foucault pendulums are difficult to implement, museum Foucault pendulum are typically at least 7 meters long. These effects are also present in our flexure based oscillators and reducing these parasitic effects, requires decreasing their frequency. This paper discusses the design and dimensioning of a new flexure based 2-DOF oscillator which can reach low frequencies of the order of 0.1[Hz]. The motion of this oscillator is approximatelyplanar, like the classical Foucault pendulum, and will have the same Foucault precession rate. The construction of a low frequency demonstrator is underway and will be followed by quantitative measurements which will examine both the Foucault effect as well as parasitic precession.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

DETC2020-22075.pdf

Type

Publisher's Version

Version

http://purl.org/coar/version/c_970fb48d4fbd8a85

Access type

openaccess

License Condition

Copyright

Size

1.17 MB

Format

Adobe PDF

Checksum (MD5)

f87d677541552852bfa18f1052dbf315

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés