  4. Micromotion-induced peri-prosthetic fluid flow around a cementless femoral stem
 
research article

Micromotion-induced peri-prosthetic fluid flow around a cementless femoral stem

Malfroy Camine, Valérie
•
Terrier, Alexandre  
•
Pioletti, Dominique  
2017
Computer Methods in Biomechanics and Biomedical Engineering

Micromotion-induced interstitial fluid flow at the bone-implant interface has been proposed to play an important role in aseptic loosening of cementless implants. High fluid velocities are thought to promote aseptic loosening through activation of osteoclasts, shear stress induced control of mesenchymal stem cells differentiation, or transport of molecules. In this study, our objectives were to characterize and quantify micromotion-induced fluid flow around a cementless femoral stem using finite element modeling. With a 2D model of the bone-implant interface and full-factorial design, we first evaluated the relative influence of material properties, and bone-implant micromotion and gap on fluid velocity. Transverse sections around a femoral stem were built from computed tomography images, while boundary conditions were obtained from experimental measurements on the same femur. In a second step, a 3D model was built from the same dataset to estimate the shear stress experienced by cells hosted in the peri-implant tissues. The full-factorial design analysis showed that local micromotion had the most influence on peak fluid velocity at the interface. Remarkable variations in fluid velocity were observed in the macrostructures at the surface of the implant in the 2D transverse sections of the stem. The 3D model predicted peak fluid velocities extending up to 2.2 mm/s in the granulation tissue and to 3.9 mm/s in the trabecular bone. Peak shear stresses on the cells hosted in these tissues ranged from 0.1 Pa to 12.5 Pa. These results offer insight into mechanical stimuli encountered at the bone-implant interface.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1080/10255842.2017.1296954
Web of Science ID

WOS:000399353100005

Author(s)
Malfroy Camine, Valérie
Terrier, Alexandre  
Pioletti, Dominique  
Date Issued

2017

Publisher

Taylor & Francis

Published in
Computer Methods in Biomechanics and Biomedical Engineering
Volume

20

Issue

7

Start page

730

End page

736

Subjects

cementless total hip arthroplasty

•

micromotion

•

interstitial fluid flow

•

femoral stem

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LBO  
Available on Infoscience
February 16, 2017
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/134336
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés