  4. Punching shear tests on compact footings with uniform soil pressure
 
research article

Punching shear tests on compact footings with uniform soil pressure

Simões, Joâo T.
•
Bujnak, Jan
•
Fernández Ruiz, Miguel
Show more
2016
Structural Concrete

Punching shear is usually the governing failure criterion for the select ion of the depth of reinforced concrete footings. Despite the fact that large experimental programmes have been performed in the past aimed at the punching strength of slender flat slabs, only a few experimental campaigns on full-scale compact reinforced concrete footings can be found in the literature. In this paper, the results of an experimental programme including 8 reinforced concrete footings with a nominal thickness of 550 mm is presented. These experiments investigated the influence of the column size, member slenderness and the presence of compression and shear reinforcement. The test s were performed using an innovative test setup to ensure a uniform soil pressure. The experimental results show that the slenderness influences the punching shear strength as well as the effectiveness of the shear reinforcement. It is also experimentally shown that an important interaction amongst bending and shear occurs for high levels of shear forces near the column (typical case of compact footings or members with large amounts of shear reinforcement). Different continuous measurements recorded during the experimental tests allow a complete description of the kinematics and strains at failure. On that basis, experimental evidence is obtained showing that crushing of the concrete struts near the column is the phenomenon that triggers the punching failure of compact footings.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1002/suco.201500175
Web of Science ID

WOS:000390245100009

Author(s)
Simões, Joâo T.
Bujnak, Jan
Fernández Ruiz, Miguel
Muttoni, Aurelio  
Date Issued

2016

Publisher

Structural Concrete

Published in
Structural Concrete
Volume

n° 4

Start page

603

End page

617

Subjects

armature de poinçonnement

•

comportement statique

•

poinçonnement

•

résistance

•

résultat d’essais

•

punching shear reinforcement

•

structural behaviour

•

punching

•

resistance

•

test result

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
IBETON  
Available on Infoscience
December 9, 2016
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/131886
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés