  4. Revisiting parallel catadioptric goniophotometers
 
conference paper

Revisiting parallel catadioptric goniophotometers

Karamata, Boris  
•
Andersen, Marilyne  
Lehmann, Ph
•
Osten, W.
Show more
2013
SPIE Optical Metrology 2013
SPIE Optical Metrology - Optical Measurement Systems For Industrial Inspection Viii

A thorough knowledge of the angular distribution of light scattered by an illuminated surface under different angles is essential in numerous industrial and research applications. Traditionally, the angular distribution of a reflected or transmitted light flux as function of the illumination angle, described by the Bidirectional Scattering Distribution Function (BSDF), is measured with a point-by-point scanning goniophotometer yielding impractically long acquisition times. Significantly faster measurements can be achieved by a device capable of simultaneously imaging the far-field distribution of light scattered by a sample onto a two-dimensional sensor array. Such an angular-to-spatial mapping function can be realized with a parallel catadioptric mapping goniophotometer (CMG). In this contribution, we formally establish the design requirement for a reliable CMG. Based on heuristic considerations we show that, to avoid degrading the angular-to-spatial function, the acceptance angle of the lens system inherent to a CMG must be smaller than 60 degrees. By means of a parametric study, we investigate the practical design limitations of a CMG caused by the constraints imposed by the properties of a real lens system. Our study reveals that the values of the key design parameters of a CMG fall within a relatively small range. This imposes the shape of the ellipsoidal reflector and drastically restricts the room for a design trade-off between the sample size and the angular resolution. We provide a quantitative analysis for the key parameters of a CMG for two relevant cases.

  • Files
  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés