Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Three-dimensional echo planar imaging with controlled aliasing: A sequence for high temporal resolution functional MRI
 
research article

Three-dimensional echo planar imaging with controlled aliasing: A sequence for high temporal resolution functional MRI

Narsude, Mayur  
•
Gallichan, Daniel  
•
Van Der Zwaag, Wietske  
Show more
2016
Magnetic Resonance in Medicine

Purpose In this work, we combine three-dimensional echo planar imaging (3D-EPI) with controlled aliasing to substantially increase temporal resolution in whole-brain functional MRI (fMRI) while minimizing geometry-factor (g-factor) losses. Theory and Methods The study was performed on a 7 Tesla scanner equipped with a 32-channel receive coil. The proposed 3D-EPI-CAIPI sequence was evaluated for: (i) image quality, compared with a conventionally undersampled parallel imaging acquisition; (ii) temporal resolution, the ability to sample and remove physiological signal fluctuations from the fMRI signal of interest and (iii) the ability to distinguish small changes in hemodynamic responses in an event-related fMRI experiment. Results Whole-brain fMRI data with a voxel size of 2 × 2 × 2 mm3 and temporal resolution of 371 ms could be acquired with acceptable image quality. Ten-fold parallel imaging accelerated 3D-EPI-CAIPI data were shown to lower the maximum g-factor losses up to 62% with respect to a 10-fold accelerated 3D-EPI dataset. FMRI with 400 ms temporal resolution allowed the detection of time-to-peak variations in functional responses due to multisensory facilitation in temporal, occipital and frontal cortices. Conclusion 3D-EPI-CAIPI allows increased temporal resolution that enables better characterization of physiological noise, thus improving sensitivity to signal changes of interest. Furthermore, subtle changes in hemodynamic response dynamics can be studied in shorter scan times by avoiding the need for jittering.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1002/mrm.25835
Web of Science ID

WOS:000384994700014

Author(s)
Narsude, Mayur  
Gallichan, Daniel  
Van Der Zwaag, Wietske  
Gruetter, Rolf  
Marques, José P.
Date Issued

2016

Publisher

Wiley-Blackwell

Published in
Magnetic Resonance in Medicine
Volume

75

Issue

6

Start page

2350

End page

2361

Subjects

CIBM-AIT

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LIFMET  
CIBM  
Available on Infoscience
July 19, 2015
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/116378
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés