We briefly categorize and compare parallel goniophotometers, which are instruments capable of simultaneously measuring the far-field distribution of light scattered by a surface or emitted by a source over a large solid angle. Little is known about the accuracy and reliability of an appealing category, the catadioptric parallel goniophotometers (CPGs), which exploit a curved reflector and a lens system. We analyzed the working principle common to all the different design configurations of a CPG and established the specifications implicitly imposed on the lens system. Based on heuristic considerations, we show that the properties of a real (thick) lens system are not fully compatible with these specifications. This causes a bias to the measurements that increases with the acceptance angle of the lens system. Depending on the angular field, the measured sample area can be drastically reduced and shifted relative to the center of the sample. To gain insights into the nature and importance of the measurement bias, it was calculated with our model implemented in MATLAB for the CPG configuration incorporating a lens system with a very large acceptance angle (fisheye lens). Our results demonstrate that, due to the spatio-angular-filtering properties of the fisheye lens, this category of CPGs is so severely biased as to give unusable measurements. In addition, our findings raise the question of the importance of the bias in the other types of CPGs that rely on a lens system with a lower acceptance angle.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1364/JOSAA.31.001040
Web of Science ID

WOS:000335494500016

Author(s)
Karamata, Boris  
Andersen, Marilyne  
Date Issued

2014

Published in
Journal of the Optical Society of America a Optics and Image Science
Volume

31

Issue

5

Start page

1084

End page

7529

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LIPID  
Available on Infoscience
June 18, 2014
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/104482
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés