Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Conferences, Workshops, Symposiums, and Seminars
  4. Low-noise high-dynamic-range single-photon avalanche diodes with integrated PQAR circuit in a standard 55 nm BCD
 
conference paper

Low-noise high-dynamic-range single-photon avalanche diodes with integrated PQAR circuit in a standard 55 nm BCD

Keshavarzian, Pouyan  
•
Gramuglia, Francesco  
•
Kizilkan, Ekin  
Show more
January 1, 2022
Advanced Photon Counting Techniques Xvi
Conference on Advanced Photon Counting Techniques XVI

Single-photon avalanche diode (SPAD) based sensors and systems enable a variety of applications in biomedical, automotive, consumer, and security domains. While several established standard technologies, which can facilitate the design of SPAD-based systems are already in existence, challenges remain for the development of deep sub-micron monolithic integration of circuits and SPADs. In this work, we present SPADs along with pixel circuits in a standard GF 55 nm BCDL process. Two different designs demonstrate the flexibility allowed by the technology for a variety of applications. Both shallow and deep junction SPADs present excellent noise performance of less than 1 cps/mu m(2) at 3 V excess bias. An integrated passive-quench active-recharge (PQAR) circuit is used in conjunction with the SPADs, which enables a dead time of less than 2 ns, easily allowing for high dynamic range applications that require > 100 Mcps such as quantum communication and information technologies. The deep and shallow junction SPADs demonstrate an afterpulsing probability of < 0.5 % and < 2 % at 3V excess bias, respectively. The dead time is adjustable through analog control of the active-recharge circuit, allowing for afterpulsing reduction to below 0.1 % while maintaining Mcps operation. The shallow junction, which has a breakdown voltage of about 18 V and a peak sensitivity at 430 nm is particularly interesting for applications requiring low supply voltage, whereas the deep SPAD, which demonstrates > 4 % photon detection probability (PDP) at 940 nm, can be implemented in LiDAR sensors that require enhanced sensitivity at near-infrared (NIR) wavelengths. The measured timing jitter of both SPADs is < 50 ps FWHM at 3 V excess bias and 780 nm.

  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés