Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Resolution and penetration depth of reflection-mode time-domain near infrared optical tomography using a ToF SPAD camera
 
research article

Resolution and penetration depth of reflection-mode time-domain near infrared optical tomography using a ToF SPAD camera

Jiang, Jingjing
•
Ackermann, Meret
•
Russomanno, Emanuele
Show more
December 1, 2022
Biomedical Optics Express

In a turbid medium such as biological tissue, near-infrared optical tomography (NIROT) can image the oxygenation, a highly relevant clinical parameter. To be an efficient diagnostic tool, NIROT has to have high spatial resolution and depth sensitivity, fast acquisition time, and be easy to use. Since many tissues cannot be penetrated by near-infrared light, such tissue needs to be measured in reflection mode, i.e., where light emission and detection components are placed on the same side. Thanks to the recent advance in single-photon avalanche diode (SPAD) array technology, we have developed a compact reflection-mode time-domain (TD) NIROT system with a large number of channels, which is expected to substantially increase the resolution and depth sensitivity of the oxygenation images. The aim was to test this experimentally for our SPAD camera-empowered TD NIROT system. Experiments with one and two inclusions, i.e., optically dense spheres of 5mm radius, immersed in turbid liquid were conducted. The inclusions were placed at depths from 10mm to 30mm and moved across the field-of-view. In the two-inclusion experiment, two identical spheres were placed at a lateral distance of 8mm. We also compared short exposure times of 1s, suitable for dynamic processes, with a long exposure of 100s. Additionally, we imaged complex geometries inside the turbid medium, which represented structural elements of a biological object. The quality of the reconstructed images was quantified by the root mean squared error (RMSE), peak signal-to-noise ratio (PSNR), and dice similarity. The two small spheres were successfully resolved up to a depth of 30mm. We demonstrated robust image reconstruction even at 1s exposure. Furthermore, the complex geometries were also successfully reconstructed. The results demonstrated a groundbreaking level of enhanced performance of the NIROT system based on a SPAD camera.

  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés