Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Portable Amperometric Perchlorate Selective Sensors with Microhole Array-water/organic Gel Interfaces
 
research article

Portable Amperometric Perchlorate Selective Sensors with Microhole Array-water/organic Gel Interfaces

Lee, Sang Hyuk
•
Kim, Hyungi
•
Girault, Hubert H.  
Show more
2013
Bulletin of the Korean Chemical Society (BKCS)

A novel stick-shaped portable sensing device featuring a microhole array interface between the polyvinylchloride- 2-nitrophenyloctylether (PVC-NPOE) gel and water phase was developed for in-situ sensing of perchlorate ions in real water samples. Perchlorate sensitive sensing responses were obtained based on measuring the current changes with respect to the assisted transfer reaction of perchlorate ions by a perchlorate selective ligand namely, bis(dibenzoylmethanato)Ni(II) (Ni(DBM)2) across the polarized microhole array interface. Cyclic voltammetry was used to characterize the assisted transfer reaction of perchlorate ions by the Ni(DBM)2 ligand when using the portable sensing device. The current response for the transfer of perchlorate anions by Ni(DBM)2 across the micro-water/gel interface linearly increased as a function of the perchlorate ion concentration. The technique of differential pulse stripping voltammetry was also utilized to improve the sensitivity of the perchlorate anion detection down to 10 ppb. This was acquired by preconcentrating perchlorate anions in the gel layer by means of holding the ion transfer potential at 0 mV (vs. Ag/AgCl) for 30 s followed by stripping the complexed perchlorate ion with the ligand. The effect of various potential interfering anions on the perchlorate sensor was also investigated and showed an excellent selectivity over Br−, NO2 −, NO3 −, CO3 2−, CH3COO− and SO4 2− ions. As a final demonstration, some regional water samples from the Sincheon river in Daegu city were analyzed and the data was verified with that of ion chromatography (IC) analysis from one of the Korean-certified water quality evaluation centers.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.5012/bkcs.2013.34.9.2577
Web of Science ID

WOS:000330330300007

Author(s)
Lee, Sang Hyuk
Kim, Hyungi
Girault, Hubert H.  
Lee, Hye Jin
Date Issued

2013

Published in
Bulletin of the Korean Chemical Society (BKCS)
Volume

34

Issue

9

Start page

2577

End page

2582

Subjects

Perchlorate selective sensor

•

Portable sensor

•

Microhole array-water/gel interface

•

Ion transfer reaction

•

Bis(dibenzoylmethanato)Ni(II)

Editorial or Peer reviewed

REVIEWED

Written at

OTHER

EPFL units
LEPA  
Available on Infoscience
October 16, 2013
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/96226
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés