On the Utility of Isotopic Fine Structure Mass Spectrometry in Protein Identification

Miladinović, Saša M.  
•
Kozhinov, Anton N.  
•
Gorshkov, Mikhail V.
Show more
2012
Analytical Chemistry

Modern mass spectrometry (MS)-based protein identification and characterization relies upon accurate mass measurements of the C-13 isotopic distributions of the enzymatically produced peptides. Interestingly, obtaining peptide elemental composition information from its isotopic fine structure mass spectrum to increase the confidence in peptide and protein identification has not yet been developed into a bottom-up proteomics-grade analytical approach. Here, we discuss the possible utility and limitations of the isotopic fine structure MS for peptide and protein identification. First, we in silica identify the peptides from the E. colt tryptic digest and show the increased confidence in peptide identification by consideration of the isotopic fine structures of these peptides as a function of mass and abundance accuracies. In the following, we demonstrate that the state-of-the-art high magnetic field Fourier transform ion cyclotron resonance (FT-ICR) MS allows a routine acquisition of the isotopic fine structure information of a number of isobaric peptide pairs, including a pair of peptides originating from E. coli. Finally, we address the practical limitation of the isotopic fine structure MS implementation in the time constraint experiments by applying an advanced signal processing technique, filter diagonalization method, to the experimental transients to overcome the resolution barrier set by the typically applied Fourier transformation. We thus demonstrate that the isotopic fine structures of peptides may indeed improve the peptide and possibly protein identification, can be produced in a routine experiment by the state-of-the-art high resolution mass spectrometers, and can be potentially obtained on a chromatographic time-scale of a typical bottom-up proteomics experiment. The latter one requires at least an order of magnitude increase in sensitivity of ion detection, which presumably can be realized using high-field Orbitrap FTMS and/or future generation of ultrahigh magnetic field FT-ICR MS equipped with harmonized ICR cells.

  • Details
  • Metrics
Type
research article
DOI
10.1021/ac2034584
Web of Science ID

WOS:000303349200026

Author(s)
Miladinović, Saša M.  
Kozhinov, Anton N.  
Gorshkov, Mikhail V.
Tsybin, Yury O.  
Date Issued

2012

Published in
Analytical Chemistry
Volume

84

Issue

9

Start page

4042

End page

4051

Subjects

Electron-Capture Dissociation

•

Filter Diagonalization Method

•

Band Phase Correction

•

High-Resolution

•

Elemental Compositions

•

Ion Abundances

•

Accurate Mass

•

Ft-Icr

•

Spectra

•

Proteomics

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LSMB  
Available on Infoscience
May 2, 2012
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/79948
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés