Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Performance of Instantaneous Microwave Analysis by Parametric Channelized Receiver Through Time Domain Monitoring
 
research article

Performance of Instantaneous Microwave Analysis by Parametric Channelized Receiver Through Time Domain Monitoring

Bres, Camille-Sophie  
•
Wiberg, Andreas O. J.
•
Zlatanovic, Sanja
Show more
2012
Journal of Lightwave Technology

For many applications, ranging from commercial, surveillance, or defense, it is essential to analyze the frequency components of a captured microwave signal over a wide bandwidth in real time and with high resolution. Various photonic approaches have been proposed for the processing of wideband microwave signals in order to overcome limitations imposed by conventional electronic frequency measurements. Here, we present the performance analysis and characterization of a parametric channelized receiver with 275 MHz resolution defined by the Fabry-Perot 3 dB bandwidth and 1 GHz step. Our approach relies on the generation of high quality copies of the RF input by self-seeding wavelength multicasting in a two-pump parametric mixer. Periodic filtering using off-the-shelf elements is then performed on the multicast beam. Ease of filtering is thus achieved by relying on frequency nondegeneracy of the newly generated copies. In this paper, instantaneous analysis of the incoming microwave signal is demonstrated by simultaneous monitoring five of the generated parametric copies while transmitting a frequency-hopping pattern. Operating margins in terms of optical and microwave powers are studied using the five-channel data simultaneously collected on a real-time oscilloscope. Dynamic range adjustments through optical power tuning of the input signal seed are demonstrated. Finally, the effects of frequency mapping detuning are observed to determine optimal operating conditions.

  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés