Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. V-band nanosecond-scale pulse reflectometer diagnostic in the TCV tokamak
 
research article

V-band nanosecond-scale pulse reflectometer diagnostic in the TCV tokamak

Molina Cabrera, Pedro Andres  
•
Coda, S.  
•
Porte, L.  
Show more
2019
Review of Scientific Instruments

This article describes the realization of a novel approach to short pulse (∼1 ns) reflectometry (SPR) recently implemented in the tokamak configuration variable tokamak. Taking advantage of a fast arbitrary waveform generator and vector-network-analyzer extension modules, the design offers flexibility regarding pulse output frequency, duration, and repetition rate. Such flexibility allows the instrument to overcome traditional SPR spatial sampling limitations while reducing hardware complexity. In order to measure the group-delay of nanosecond-scale pulses, both traditional analog and novel digital sampling techniques have been explored. A group-delay range resolution of 17 ps (2.6 mm) in average over the V-band has been achieved with both timing techniques against a waveguide mirror featuring 10 dB power fluctuations. Direct pulse sampling during L-mode plasmas shows that reflected pulse widths increase only by 4% in average. However, pulse width dispersion does occur in L-mode plasmas and leads to an increase in the group-delay uncertainty up to 40 ps (6 mm). Raw histograms of group-delay data show interesting qualitative changes from the L mode to the H-mode. Frequency spectra of group-delay data allow the identification of macroscopic density fluctuations as well as edge quasicoherent modes during edge-localized mode-free H-modes. Finally, fast changes to the density profile have been measured with microsecond time resolution and subcentimeter spatial resolution in both O and X-mode polarizations.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1063/1.5094850
Author(s)
Molina Cabrera, Pedro Andres  
Coda, S.  
Porte, L.  
Smolders, A.
Date Issued

2019

Published in
Review of Scientific Instruments
Volume

90

Issue

12

Article Number

123501

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
SPC  
RelationRelated workURL/DOI

IsContinuedBy

V-band nanosecond-scale pulse reflectometer diagnostic in the TCV tokamak [Correction] (vol 90, 123501, 2019)

https://infoscience.epfl.ch/handle/20.500.14299/167275
Available on Infoscience
December 18, 2019
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/164069
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés