Metrology techniques for the verification of the alignment of the EU gyrotron prototype for ITER

Sanchez, Francisco
•
Albajar, Ferran
•
Lo Bue, Alessandro
Show more
January 1, 2019
20Th Joint Workshop On Electron Cyclotron Emission And Electron Cyclotron Resonance Heating (Ec20)
20th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC)

The EU gyrotron for the ITER Electron Cyclotron (EC) heating system has been developed in coordinated efforts of the EGYC Consortium, Thales ED (TED) and Fusion for Energy (F4E) and under the supervision of ITER Organization Central Team. After the successful verification of the design of the 1MW, 170 GHz hollow cylindrical cavity gyrotron operating at the nominal TE32,9 mode with a short pulse gyrotron prototype at KIT, an industrial CW gyrotron prototype was manufactured by TED and tested at similar to 0.8 MW output power and 180 s pulse duration, which is the limit of the HV power supply currently available at KIT. The experiments are being continued at SPC in 2018 to extend further the pulse duration, taking advantage of the existing CW full-power capabilities of the gyrotron test facility recently upgraded for the FALCON project. The gyrotron cavity interaction is very sensitive to the alignment of the internal mechanical parts of the gyrotron tube with the magnetic field generated by the superconducting magnet within a typical range of 0.2 - 0.5 mm. The control of the tolerances and deformations becomes therefore critical to achieving the target performances. With the EU gyrotron prototype it was possible to adjust the alignment of the gyrotron tube with respect to the magnetic field axis during the installation and commissioning phase. The actual shift and tilt movements were verified using advanced metrology methods such as photogrammetry. In this paper, the alignment control techniques and procedures will be discussed also in view of enhancing the reproducibility of gyrotron performance during series production.

  • Files
  • Details
  • Metrics
Type
conference paper
DOI
10.1051/epjconf/201920304015
Web of Science ID

WOS:000570226000053

Author(s)
Sanchez, Francisco
Albajar, Ferran
Lo Bue, Alessandro
Alberti, Stephano  
Avramidis, Konstantinos
Bonicelli, Tullio
Bruschi, Alex
Gantenbein, Gerd
Hogge, Jean-Philippe  
Illy, Stefan
Show more
Date Issued

2019-01-01

Publisher

E D P SCIENCES

Publisher place

Cedex A

Published in
20Th Joint Workshop On Electron Cyclotron Emission And Electron Cyclotron Resonance Heating (Ec20)
Series title/Series vol.

EPJ Web of Conferences

Volume

203

Start page

04015

Subjects

Physics, Fluids & Plasmas

•

Physics, Condensed Matter

•

Physics

Note

This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0.

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
SPC  
Event nameEvent placeEvent date
20th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC)

Greifswald, GERMANY

May 14-17, 2018

Available on Infoscience
October 14, 2020
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/172452
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés