Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Conferences, Workshops, Symposiums, and Seminars
  4. Optical Urea Sensing in Sweat for Kidney Healthcare by Sensitive and Selective Non-enhanced Raman Spectroscopy
 
conference paper

Optical Urea Sensing in Sweat for Kidney Healthcare by Sensitive and Selective Non-enhanced Raman Spectroscopy

Golparvar, Ata  
•
Boukhayma, Assim  
•
Petrelli, Mattia
Show more
January 1, 2023
Optical Diagnostics And Sensing Xxiii
Conference on Optical Diagnostics and Sensing XXIII - Toward Point-of-Care Diagnostics

Sweat biomarker analysis has attracted much interest in applications ranging from sports to wearable healthcare. Among all the sweat biomolecules, abnormal urea levels have been linked to several complications, particularly renal dysfunction. Here, we report the first application of non-enhanced (i.e., spontaneous) Raman spectroscopy for urea sensing in sweat. The proposed method eliminates the need for plasmonic surface fabrication for surface enhancement or bulky ultrashort-pulsed lasers for coherent enhancement. The exploitation of non-enhanced Raman was made possible because the concentration of urea in sweat, due to sweat physiology, is significantly higher with respect to urea concentration in blood. To demonstrate the feasibility of the proposed technique, we first identified the most intense urea Raman band. We then investigated the feasibility of the single-band integration data analysis to predict urea concentration in buffer solution. Single-band data analysis holds great promise for instrument miniaturization and facilitates the effort toward mobile and wearable photonic technologies. Next, we provided firm evidence of the high selectivity of the proposed sensing concept with human sweat in vitro. Finally, we reported successful ex vivo physiological sweat urea monitoring (with artificial eccrine perspiration, the closest mimic to true human eccrine sweat) on a porcine phantom, which mimics human skin, proving the potential of the proposed technique for in situ sweat urea analysis. We recorded an excellent linear calibration for urea concentrations from 0 to 60 mM with R-2 value of 0.9973, high sensitivity of 3521 count/mM, and low detection and quantification limits of 0.47 and 1.33 mM, respectively.

  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés