  4. Fire performance of water-cooled cellular GFRP columns
 
conference paper

Fire performance of water-cooled cellular GFRP columns

Bai, Y.  
•
Keller, T.  
2011
Advances in FRP composites in civil engineering
5th International Conference on FRP Composites in Civil Engineering (CICE 2010)

Structural fire endurance experiments were conducted on full-scale cellular glass fiber reinforced (GFRP) columns under axial compression and subjected to ISO 834 fire exposure from one side. Unprotected columns could resist fire for more than 30 min, which is sufficient for occupants to be evacuated from smaller buildings. The closed cellular cross section prevented the rapid heating of the webs, which could therefore continue stabilizing the face sheet on the cold side against buckling. Water cooling was proved to offer an effective active fire protection system. The structural function of the column could be maintained for two hours. Previously developed models were capable of predicting the time-dependent temperature responses, modulus degradation and time-to-failure.

  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés