Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. SA2RAGE: A new sequence for fast B(1) (+) -mapping
 
research article

SA2RAGE: A new sequence for fast B(1) (+) -mapping

Eggenschwiler, Florent  
•
Kober, Tobias  
•
Magill, Arthur W.  
Show more
2012
Magnetic Resonance in Medicine

At high magnetic field strengths (≥3T), the radiofrequency wavelength used in MRI is of the same order of magnitude of (or smaller than) the typical sample size, making transmit magnetic field (B 1+) inhomogeneities more prominent. Methods such as radiofrequency-shimming and transmit SENSE have been proposed to mitigate these undesirable effects. A prerequisite for such approaches is an accurate and rapid characterization of the B 1+ field in the organ of interest. In this work, a new phase-sensitive three-dimensional B 1+-mapping technique is introduced that allows the acquisition of a 64 × 64 × 8 B 1+-map in ∼20 s, yielding an accurate mapping of the relative B 1+ with a 10-fold dynamic range (0.2-2 times the nominal B 1+). Moreover, the predominant use of low flip angle excitations in the presented sequence minimizes specific absorption rate, which is an important asset for in vivo B 1+-shimming procedures at high magnetic fields. The proposed methodology was validated in phantom experiments and demonstrated good results in phantom and human B 1+-shimming using an 8-channel transmit-receive array. Magn Reson Med, 2011. © 2011 Wiley-Liss, Inc.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1002/mrm.23145
Web of Science ID

WOS:000304086000013

Author(s)
Eggenschwiler, Florent  
Kober, Tobias  
Magill, Arthur W.  
Gruetter, Rolf  
Marques, José P.
Date Issued

2012

Publisher

Wiley

Published in
Magnetic Resonance in Medicine
Volume

67

Issue

6

Start page

1609

End page

19

Subjects

Sa2Rage

•

B?1+-mapping

•

B?1+-shimming

•

Field In-Vivo

•

Steady-State

•

Flip-Angle

•

Radiofrequency Field

•

Rf-Pulse

•

Human Brain

•

T-1

•

Excitation

•

Optimization

•

Transmitter

•

CIBM-AIT

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
CIBM  
LIFMET  
Available on Infoscience
May 26, 2012
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/80805
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés