Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Fast model-based T-2 mapping using SAR-reduced simultaneous multislice excitation
 
research article

Fast model-based T-2 mapping using SAR-reduced simultaneous multislice excitation

Hilbert, Tom  
•
Schulz, Jenni
•
Marques, Jose P.  
Show more
July 4, 2019
Magnetic Resonance in Medicine

Purpose To obtain whole-brain high-resolution T-2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. Methods A multi-echo spin-echo sequence was modified to acquire multiple slices simultaneously, ensuring low specific absorption rate requirements. In addition, the acquisition was undersampled to achieve further acceleration. Data were reconstructed by subsequently applying parallel imaging to separate signals from different slices, and a model-based reconstruction to estimate quantitative T-2 from the undersampled data. The signal model used is based on extended phase graph simulations that also account for nonideal slice profiles and B-1 inhomogeneity. In vivo experiments with 3 healthy subjects were performed to compare accelerated T-2 maps to fully sampled single-slice acquisitions. The accuracy of the T-2 values was assessed with phantom experiments by comparing the T-2 values to single-echo spin-echo measurements. Results In vivo results showed that conventional multi-echo spin-echo, simultaneous multislice, and undersampling result in similar mean T-2 values within regions of interest. However, combining simultaneous multislice and undersampling results in higher SDs (about 7 ms) in comparison to a conventional sequence (about 3 ms). The T-2 values were reproducible between scan and rescan (SD < 1.2 ms) within subjects and were in similar ranges across subjects (SD < 4.5 ms). Conclusion The proposed method is a fast T-2 mapping technique that enables whole-brain acquisitions at 0.7-mm in-plane resolution, 3-mm slice thickness, and low specific absorption rate in 2 minutes.

  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés