Modelling city-scale facade leaching of biocide by rainfall
A methodology is presented for estimating, at the city scale, the amount of biocide released from facades during rain events. The methodology consists of two elements. First, leaching of a single facade is simulated using a two-region model, one region for the biocide in the facade and the other for that in the flow over the facade surface. In the latter region, water advection moves the biocide to the base of the facade, and so into the environment. Rates of detachment and deposition define the exchange process between the two regions. The two-region model was calibrated on laboratory data, and afterward applied at city scale to Lausanne, Switzerland (200,000 inhabitants). The city-scale application uses the second element of the methodology, which consists of an estimate of the exposure of the city’s facades to rainfall, and relating that rainfall to the overfacade flow in the calibrated single-facade model. This results in a straightforward translation of over-facade flow volume to facade paint age, a necessary connection since facade leaching is dependent on paint age. For Lausanne, it was estimated that approximately 30% of the mass of biocides applied annually is released into the environment
1-s2.0-S0043135412002382-main.pdf
Publisher's Version
openaccess
767.87 KB
Adobe PDF
2bf353344c2241fdb6381016deffee68
Facade_Leaching_1.pdf
Preprint
openaccess
294.62 KB
Adobe PDF
b320082d71032412ca828cb02e985597