research article
Flow Boiling in Horizontal Tubes. Part 1; Development of a Diabatic Two–Phase Flow Pattern Map
An improved two-phase flow pattern map is proposed for evaporation in horizontal tubes. The new map was developed based on flow pattern data for five different refrigerants covering a wide range of mass velocities and vapor qualities. The new map is valid for both adiabatic and diabatic (evaporating) flows and accurately identifies about 96% of the 702 data points. In addition, the new flow pattern map includes the prediciton of the onset of dryout at the top of the tube during evaporation inside horizontal tubes as a function of heat flux and flow parameters.
Type
research article
Web of Science ID
WOS:000072527000018
Authors
Publication date
1998
Published in
Volume
120
Issue
1
Start page
140
End page
147