  4. Demonstration of a sparse sensor placement technique to the limited diagnostic set in a fusion power plant
 
research article

Demonstration of a sparse sensor placement technique to the limited diagnostic set in a fusion power plant

Raukema, J.
•
Bosman, T. O. S. J.
•
Classen, I. G. J.
Show more
February 23, 2024
Fusion Engineering And Design

DEMO will have a limited diagnostic set for optimization of reactor performance, and limited diagnostic coverage due to challenging reactor conditions. This poses challenges for control, especially for detachment control which is planned to be performed with a limited set of spectroscopic lines -of -sight. To demonstrate mitigation of the coverage problem, we have implemented a sparse sensor placement technique on TCV for the case of spectroscopy. Experimental CIII 2D emissivity profiles from the MANTIS multispectral imaging system at TCV are used to create a synthetic spectroscopy system, with DEMO -relevant lines -of -sight. This synthetic diagnostic is validated through comparison with spectroscopic measurements in TCV. The sparse sensor placement algorithm takes as input the radiance calculated for a large set of lines -of -sight, resolved in time. It provides a method to reconstruct an emission profile along the divertor leg based on measurements from only a few lines -of -sight. We demonstrate that it is feasible to use a calibration based on either experimental data or simulated emissivities from SOLPS-ITER. As a result, for DEMO, the line -of -sight selection and a mathematical basis for reconstruction can be obtained before the reactor is turned on. The sparse sensor placement method can also be applied to estimate other physical quantities from emission measurements, if they have a oneto-one relationship with the shape of the emission profile along the divertor leg. As an example, the peak target current density obtained with Langmuir probes can be reconstructed using spectroscopy measurements. Lastly, the geometry of the lines -of -sight plays an important role in proper emission profile reconstruction. It should be tailor-made to the used magnetic configuration to measure the emission profile accurately, and the technique described here offers a route for performing this optimization.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.fusengdes.2024.114271
Web of Science ID

WOS:001202067100001

Author(s)
Raukema, J.
•
Bosman, T. O. S. J.
•
Classen, I. G. J.
•
Wijkamp, T. A.
•
Perek, Artur  
•
Derks, G. L.
•
Koenders, J. T. W.
•
Martinelli, Lorenzo  
•
Jaspers, R. J. E.
Corporate authors
TCV Team
Date Issued

2024-02-23

Publisher

Elsevier Science Sa

Published in
Fusion Engineering And Design
Volume

201

Article Number

114271

Subjects

Technology

•

Divertor

•

Detachment

•

Demo

•

Spectroscopy

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
SPC  
FunderGrant Number

European Commission or SERI

Available on Infoscience
May 1, 2024
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/207685
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés