To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 x 1034 cm-2 s-1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionising energy loss of up to ?eq = 3.5 x 1016 cm-2. This paper focuses on planar pixel sensor design and qualification up to a fluence of ?eq = 1.4 x 1016 cm-2. For the development of appropriate planar pixel sensors an R&D program was initiated, which includes n+-p sensors on 150 mm (6") wafers with an active thickness of 150 mu m with pixel sizes of 100 x 25 mu m2 and 50 x 50 mu m2 manufactured by Hamamatsu Photonics K.K. (HPK). Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfil the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 x 50 mu m2 pixels is measured as 4.0 mu m for non-irradiated samples, and 6.3 mu m after irradiation to ?eq = 7.2 x 1015 cm-2.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.nima.2023.168326
Web of Science ID

WOS:001122390400001

Author(s)
Adam, W.
Bergauer, T.
Damanakis, K.
Dragicevic, M.
Fruehwirth, R.
Steininger, H.
Beaumont, W.
Darwish, M. R.
Janssen, T.
Kello, T.
Show more
Date Issued

2023-08-01

Publisher

Elsevier

Published in
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume

1053

Article Number

168326

Subjects

Technology

•

Physical Sciences

•

Pixel

•

Silicon

•

Sensors

•

Cms

•

Hl-Lhc

•

Radiation Hardness

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LPHE  
Available on Infoscience
March 18, 2024
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/206290
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés