  4. High power mm-wave loss measurements of ITER ex-vessel waveguide components at the FALCON test facility at the Swiss Plasma Center
 
conference paper

High power mm-wave loss measurements of ITER ex-vessel waveguide components at the FALCON test facility at the Swiss Plasma Center

Goodman, Timothy P.  
•
Torreblanca, Humberto  
•
Borderas, Cinta Marraco  
Show more
January 1, 2023
21St Joint Workshop On Electron Cyclotron Emission And Electron Cyclotron Resonance Heating, Ec21
21st Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (EC)

Many future fusion devices will rely heavily, if not solely, on electron cyclotron (EC) heating subsystems to provide bulk heating, instability control (neoclassical tearing mode (NTM) stabilization), and thermal instability control. Efficient use of the installed heating power (gyrotrons) requires low-loss transmission of the power over 100s of meters since the mm-wave sources need to be installed where the stray magnetic field has a small amplitude. Transmission lines are used to propagate the mm-wave power over this long distance. Quasi-optical techniques (mirrors) are used at W7X and are planned for DTT, for example. Guided components are installed at DIII-D, TCV and elsewhere and are planned at JT60SA and ITER. High power test facilities exist to evaluate the power transmission of assemblies of guided components (transmission lines). The European test facility FALCON was setup by Switzerland and Fusion for Energy (F4E) in Lausanne Switzerland at the Swiss Plasma Center (SPC) in the Ecole Polytechnique Federale de Lausanne (EPFL). Operations are funded through a framework contract with F4E. SPC operates the facility. Two ITER-class 170GHz gyrotrons are housed within the facility and used to evaluate the thermal behaviour of components provided by various ITER partners. Loss measurements are presented for miter bends and waveguides of several materials at two different diameters. The results are used to model the expected losses in the ITER ex-vessel waveguides (EW) of all five EC launchers.Many future fusion devices will rely heavily, if not solely, on electron cyclotron (EC) heating subsystems to provide bulk heating, instability control (neoclassical tearing mode (NTM) stabilization), and thermal instability control. Efficient use of the installed heating power (gyrotrons) requires low-loss transmission of the power over 100s of meters since the mm-wave sources need to be installed where the stray magnetic field has a small amplitude. Transmission lines are used to propagate the mm-wave power over this long distance. Quasi-optical techniques (mirrors) are used at W7X and are planned for DTT, for example. Guided components are installed at DIII-D, TCV and elsewhere and are planned at JT60SA and ITER. High power test facilities exist to evaluate the power transmission of assemblies of guided components (transmission lines). The European test facility FALCON was setup by Switzerland and Fusion for Energy (F4E) in Lausanne Switzerland at the Swiss Plasma Center (SPC) in the Ecole Polytechnique Federale de Lausanne (EPFL). Operations are funded through a framework contract with F4E. SPC operates the facility. Two ITER-class 170GHz gyrotrons are housed within the facility and used to evaluate the thermal behaviour of components provided by various ITER partners. Loss measurements are presented for miter bends and waveguides of several materials at two different diameters. The results are used to model the expected losses in the ITER ex-vessel waveguides (EW) of all five EC launchers.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

epjconf_ec212023_04010.pdf

Type

Publisher's Version

Version

http://purl.org/coar/version/c_970fb48d4fbd8a85

Access type

openaccess

License Condition

CC BY

Size

16.48 MB

Format

Adobe PDF

Checksum (MD5)

68ff114ca125ebfa43e52e19a49a0806

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés