Assessing the value of kinetic results from biochemical methane potential tests: Reproducibility from a large inter-laboratory study
Kinetic information extracted from biochemical methane potential (BMP) tests is often reported but its value is unclear. Inter-laboratory reproducibility provides a useful indication of its value. Here we extracted estimates of the first-order rate constant ๐ from 1259 methane production curves collected in a large inter-laboratory study on BMP in order to quantify reproducibility. Reproducibility in ๐ was poor; relative standard deviation was 50โ140%. Substrate comparisons ( ๐ for one substrate compared to another) also had low reproducibility, regardless of low ๐ values from inferential statistical tests. The use of a shared inoculum did not improve reproducibility in ๐ . We conclude that ๐ estimates from BMP tests only partially reflect intrinsic substrate properties. Therefore, interpretation and application of batch kinetic results should be done cautiously.
Cite this item
Hafner, S. D., Astals, S., Holliger, C., Koch, K., Nielsen, L., Refsahl, L., & Weinrich, S. (2022). Assessing the value of kinetic results from biochemical methane potential tests: Reproducibility from a large inter-laboratory study. Cleaner Chemical Engineering, 4, Article 100065. https://doi.org/10.1016/j.clce.2022.100065
Click Copy to copy the citation, or select the text manually.
1-s2.0-S2772782322000638-main.pdf
Publisher
Published version
openaccess
CC BY
886.95 KB
Adobe PDF
83fd8cf076f085476dabf09b24bc48fd