Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers

Akcelyan, Sarven
•
Lignos, Dimitrios G.  
January 1, 2023
Buildings

This paper presents quantitative information on the effectiveness of seismic retrofit solutions using bilinear oil dampers for seismically deficient existing tall steel buildings. For this purpose, a benchmark 40-story steel space moment-resisting frame building is studied that represents 1970s design practice in North America. Rigorous seismic performance assessment based on ASCE 41 recommendations reveals a high collapse risk for the existing building. The local engineering demand parameters are comprehensively assessed to quantify the impact of seismic retrofit on steel columns and column splices, which are particularly vulnerable due to the time of construction. Multiple retrofit schemes are explored with numerous damping levels and vertical damping distribution methods. The dampers are designed via a recently developed multi-degree-of-freedom performance curves method. A new balanced vertical damping method is proposed to account for the effects of frame inelasticity. This strongly depends on the supplemental damping level, and it determines the effectiveness of the employed vertical damping distribution method. The results indicate that the proposed retrofit strategies can minimize the collapse risk of the tall building. It is shown that the balanced vertical damping distribution method provides the most uniform drift distribution along the building height. Despite the reduction in story drift ratios, the axial force demand in exterior columns remains relatively high in the bottom stories regardless of the seismic retrofit solution. On the other hand, bilinear oil dampers produce relative constant forces despite exhibiting higher velocity demands than expected.

  • Details
  • Metrics
Type
research article
DOI
10.3390/buildings13010139
Web of Science ID

WOS:000917056700001

Author(s)
Akcelyan, Sarven
Lignos, Dimitrios G.  
Date Issued

2023-01-01

Publisher

MDPI

Published in
Buildings
Volume

13

Issue

1

Start page

139

Subjects

Construction & Building Technology

•

Engineering, Civil

•

Construction & Building Technology

•

Engineering

•

supplemental damping

•

bilinear oil dampers

•

seismic retrofit

•

collapse risk

•

performance-based design

•

tall buildings

•

viscous dampers

•

performance

•

design

•

protection

•

splices

•

models

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
RESSLAB  
Available on Infoscience
February 13, 2023
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/194770
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés