Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Chemical and isotopic analysis of hydrocarbon gas at trace levels. Methodology and results
 
research article

Chemical and isotopic analysis of hydrocarbon gas at trace levels. Methodology and results

Huiban, Yvon
•
Noirez, Sonia
•
Prinzhofer, Alain
Show more
July 1, 2009
Chemical Geology

Isotopic mass spectrometry coupled online with gas chromatography (GC-C-IRMS) permits measurement of relative proportions of gaseous hydrocarbon (CH4 to C4H10) and CO2, and determination of carbon isotope ratio of hydrocarbon molecules. Access to these parameters provides valuable information about the source and the genesis of naturally-occurring gas, as well as on post-formation physico-chemical processes which might have taken place in the geological environment. In particular, it is possible to distinguish hydrocarbon gas of bacterial origin from that of thermogenic origin based on proportion and carbon isotope ratio of methane as measured by GC-C-IRMS. However, in samples containing very low amounts of hydrocarbons (from 1 ppm to 1000 ppm), accurate measurement of isotope ratios is often impossible due to the limitations of conventional GC-C-IRMS techniques using direct sample introduction. A technique was developed to overcome this limitation. It is based on a novel approach allowing pre-concentration of hydrocarbons prior to GC-C-IRMS analysis. The pre-concentration step consists in selective trapping of hydrocarbon molecules on a cold adsorbent phase, and removal of non-adsorbed gases (N2, O2, Ar,...). In a second step, pre-concentrated alkanes are desorbed, and released in an inert carrier gas, focused through a capillary and introduced into the GC-C-IRMS for chromatographic separation and measurement of concentration and carbon isotope composition of each individual carbon molecule. In order to achieve sufficient accuracy, several operating conditions are of prime importance, including sufficient signal intensity, well defined peak shape and low signal/noise ratio. Accurate measurements can be performed on samples as small as 10 cm3 of bulk gas in standard conditions, with concentrations as low as 1 ppm of methane, 0.5 ppm of ethane and 0.3 ppm of propane and butane. Total analytical uncertainty on δ13C measurements ranges from ± 0.2‰ to ± 1.5‰, depending on the hydrocarbon molecule. © 2009 Elsevier B.V. All rights reserved.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.chemgeo.2009.04.013
Web of Science ID

WOS:000268958800010

Author(s)
Huiban, Yvon
Noirez, Sonia
Prinzhofer, Alain
Girard, Jean Pierre
Chappellaz, Jerome
Date Issued

2009-07-01

Publisher

Elsevier BV

Published in
Chemical Geology
Volume

265

Issue

3-4

Start page

363

End page

368

Subjects

carbon isotope ratio

•

chemical analysis

•

concentration (composition)

•

desorption

•

ethane

•

gas chromatography

•

hydrocarbon

•

hydrocarbon entrapment

•

isotopic analysis

•

mass spectrometry

•

methane

•

propane

•

separation

•

signal-to-noise ratio

•

Bacteria (microorganisms)

Editorial or Peer reviewed

REVIEWED

Written at

OTHER

EPFL units
SENSE  
Available on Infoscience
November 23, 2022
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/192602
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés