Abstract

Full conversion from ohmic to runaway electron (RE) driven current was observed in the tokamak a configuration variable (TCV) following massive injection of neon through a disruption mitigation valve into a low-density limited circular plasma. Following a partial disruption, a stable 200 kA RE beam is maintained for more than 1 s. Controlled ramp-down of the RE beam with adjustable decay rate was demonstrated. Control of the beam vertical position was achieved down to a RE current of 20 kA. RE beam formation is observed in elongated plasma configurations up to kappa = 1.5. A reproducible scenario for RE beam generation without loss of circulating current is of particular interest for disruption modelling applications.