Thermal resistance of the ventilated air-spaces behind external claddings; theoretical definition and a parametric study
The presence of a ventilated air cavity between the external cladding and the wall core of a wall assembly can have a varying contribution to the thermal performance of the building envelope. In particular, the thermal resistance of a ventilated air-space is a dynamic parameter that is influenced by various thermo-physical parameters. In this study, a theoretical definition of the thermal resistance of a ventilated air-space behind an external cladding is introduced, employing a non-linear network of thermal resistances in the air-space. A numerical code is developed for the steady-state condition and verified with data from hot box tests available in the literature. Thereafter, a parametric analysis is performed based on the air change rate in the cavity (0 to 1000 1/h), type of the external cladding (brick and vinyl siding), seasonal variation (summer and winter conditions), and presence of the reflective insulation. The results are compared with a closed cavity to see the efficiency of the ventilation in the air-space. The results confirm that the theoretical thermal resistance of the ventilated air-space is a function of multiple factors, and its magnitude varies under different conditions.
Rahiminejad_2021_J._Phys. _Conf._Ser._2069_012197.pdf
Publisher's version
openaccess
CC BY
808.71 KB
Adobe PDF
6f829c87b412b0fc4290e41e6391dcbb