Ug-value and edge heat loss of triple glazed insulating glass units:A comparison between measured and declared values

Wakili, K. Ghazi
•
Raedle, W.
•
Krammer, A.  
Show more
December 1, 2021
Journal Of Building Engineering

Triple glazed low-e coated insulating glass units with argon filling of five different suppliers on the European market with a declared thermal transmittance in the undisturbed centre of glass (Ug-value) of 0.6 W/m(2)K have been purchased from resellers and tested in a guarded hot plate at vertical position. The measured results showed deviations towards higher values for all 5 types. These have been analysed by recurring to the determination of the two main factors namely the gas mixture in the two cavities and the emissivity of the coated glass panes. Nondestructive measuring methods for gas mixture analysis and standardized calculation methods for the Ug-value have been used to analyse the influence of these two factors. In a further step the edge heat loss due to the spacer of the insulating glass units has been measured by using two "halves" of each glazing type with a double edge running through the middle of the measured sample. This was done following a standardized test method for the determination of the edge heat loss of Vacuum Insulation Panels (VIP). Finally, pieces of the coated glass panes were cut out of the glazing units and their emissivity measured with both an infrared spectrometer and an emissiometer. Results showed an increased emissivity value for the coated surfaces leading to higher U-g values than measured. This is partly due to the exposure to air and the possible degradation of the coating. The investigation shows non-destructive emissivity determination is needed to get more accurate in-situ emissivity values of the coatings.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.jobe.2021.103031
Web of Science ID

WOS:000701641500002

Author(s)
Wakili, K. Ghazi
•
Raedle, W.
•
Krammer, A.  
•
Uehlinger, A.
•
Schueler, A.  
•
Stoeckli, Th.
Date Issued

2021-12-01

Publisher

ELSEVIER

Published in
Journal Of Building Engineering
Volume

44

Article Number

103031

Subjects

Construction & Building Technology

•

Engineering, Civil

•

Engineering

•

ug-value

•

guarded hot plate

•

gas mixture

•

surface emissivity

•

linear thermal transmittance

•

triple glazing

•

thermal performance

•

windows

Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LESO-PB  
Available on Infoscience
October 23, 2021
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/182419
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés