Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Instrumented 5-Time Sit-To-Stand Test: Parameters Predicting Serious Falls beyond the Duration of the Test
 
research article

Instrumented 5-Time Sit-To-Stand Test: Parameters Predicting Serious Falls beyond the Duration of the Test

Atrsaei, Arash  
•
Paraschiv-Ionescu, Anisoara  
•
Krief, Helene
Show more
September 16, 2021
Gerontology

Background: Falls are a major cause of injuries in older adults. To evaluate the risk of falls in older adults, clinical assessments such as the 5-time sit-to-stand (5xSTS) test can be performed. The development of inertial measurement units (IMUs) has provided the possibility of a more in-depth analysis of the movements’ biomechanical characteristics during this test. The goal of the present study was to investigate whether an instrumented 5xSTS test provides additional information to predict multiple or serious falls compared to the conventional stopwatch-based method. Methods: Data from 458 community-dwelling older adults were analyzed. The participants were equipped with an IMU on the trunk to extract temporal, kinematic, kinetic, and smoothness movement parameters in addition to the total duration of the test by the stopwatch. Results: The total duration of the test obtained by the IMU and the stopwatch was in excellent agreement (Pearson’s correlation coefficient: 0.99), while the total duration obtained by the IMU was systematically 0.52 s longer than the stopwatch. In multivariable analyses that adjusted for potential confounders, fallers had slower vertical velocity, reduced vertical acceleration, lower vertical power, and lower vertical jerk than nonfallers. In contrast, the total duration of the test measured by either the IMU or the stopwatch did not differ between the 2 groups. Conclusions: An instrumented 5xSTS test provides additional information that better discriminates among older adults those at risk of multiple or serious falls than the conventional stopwatch-based assessment.

  • Details
  • Metrics
Type
research article
DOI
10.1159/000518389
Author(s)
Atrsaei, Arash  
Paraschiv-Ionescu, Anisoara  
Krief, Helene
Henchoz, Yves
Santos-Eggimann, Brigitte
Büla, Christophe
Aminian, Kamiar  
Date Issued

2021-09-16

Published in
Gerontology
Start page

1

End page

14

Subjects

Five-time sit-to-stand

•

Inertial sensor

•

Wearables

•

Risk of falls

•

Older adults

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LMAM  
Available on Infoscience
September 16, 2021
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/181454
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés