Robust myelin water imaging from multi-echo T2 data using second-order Tikhonov regularization with control points
Myelin water imaging is an MRI technique used to quantify myelination in the brain. The state-of-the-art reconstruction method is based on non-negative least squares optimization with zero-order Tikhonov regularization. In this study, a second-order Tikhonov regularization approach with control points was examined. This penalty term is more efficient for promoting smooth solutions while minimizing the contamination between myelin and non-myelin components. The performance of the proposed algorithm was investigated on in-vivo and ex-vivo multi-echo T2 data. It exhibited a higher correlation with histology than the state-of-the-art method. Its stability was studied using scan-rescan data.