  4. Lactate measurement by neurochemical profiling in the dorsolateral prefrontal cortex at 7T: accuracy, precision, and relaxation times
 
research article

Lactate measurement by neurochemical profiling in the dorsolateral prefrontal cortex at 7T: accuracy, precision, and relaxation times

Dehghani, Masoumeh  
•
Do, Kim Q.
•
Magistretti, Pierre  
Show more
2020
Magnetic Resonance in Medicine

Purpose This assesses the potential of measuring lactate in the human brain using three non-editing MRS methods at 7T and compares the accuracy and precision of the methods. Methods H-1 MRS data were measured in the right dorsolateral prefrontal cortex using a semi-adiabatic spin-echo full-intensity acquired localized sequence with three different protocols: (I) TE = 16 ms, (II) TE = 110 ms, and (III) TE = 16 ms, TI = 300 ms. T-1 and T-2 relaxation times of lactate were also measured. Simulated spectra were generated for three protocols with known concentrations, using a range of spectral linewidths and SNRs to assess the effect of data quality on the measurement precision and accuracy. Results Lactate was quantified in all three protocols with mean Cramer-Rao lower bound of 8% (I), 13% (II), and 7% (III). The T-1 and T-2 relaxation times of lactate were 1.9 +/- 0.2 s and 94 +/- 13 ms, respectively. Simulations predicted a spectral linewidth-associated underestimation of lactate measurement. Simulations, phantom and in vivo results showed that protocol II was most affected by this underestimation. In addition, the estimation error was insensitive to a broad range of spectral linewidth with protocol I. Within-session coefficient of variances of lactate were 6.1 +/- 7.9% (I), 22.3 +/- 12.3% (II), and 5.1 +/- 5.4% (III), respectively. Conclusion We conclude that protocols I and III have the potential to measure lactate at 7T with good reproducibility, whereas the measurement accuracy and precision depend on spectral linewidth and SNR, respectively. Moreover, simulation is valuable for the optimization of measurement protocols in future study design and the correction for measurement bias.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

postprint.pdf

Type

Postprint

Version

http://purl.org/coar/version/c_ab4af688f83e57aa

Access type

openaccess

License Condition

n/a

Size

985.43 KB

Format

Adobe PDF

Checksum (MD5)

6f0fb15097719d1ab60557c6ff2590d4

Loading...
Thumbnail Image
Name

Supplementary.pdf

Type

Postprint

Version

http://purl.org/coar/version/c_ab4af688f83e57aa

Access type

openaccess

License Condition

n/a

Size

1.3 MB

Format

Adobe PDF

Checksum (MD5)

45343570fac9fa60b8fbd7af355bf32b

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés