  4. 35 years of photovoltaics: Analysis of the TISO-10-kW solar plant, lessons learnt in safety and performance-Part 1
 
research article

35 years of photovoltaics: Analysis of the TISO-10-kW solar plant, lessons learnt in safety and performance-Part 1

Virtuani, Alessandro  
•
Caccivio, Mauro
•
Annigoni, Eleonora  
Show more
April 1, 2019
Progress In Photovoltaics

The TISO-10-kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. Its history is well documented, and the full set of modules has been tested indoors at regular intervals over the years. After 35 years of operation, we observe an increase in the degradation rates and that the distributions of modules' performances are drastically changing compared with previous years. Two groups of modules can be observed: (a) group 1: 21.5% of the modules show a very modest degradation, described by a Gaussian distribution with mean yearly power degradation of only -0.2%/y. (b) Group 2: 72.9% of the modules form a negatively skewed distribution with a long tail described by mode (-0.54%/y), median (-0.62%/y), and mean (-0.69%/y) values. In earlier years, decreases in performances could strongly be correlated to losses in fill factor (FF). After 35 years, the situation changes and, for a subset of modules, losses in the current (Isc) are superimposed to losses in FF. The reasons for this will become clearer in part 2, where we will present results of a detailed visual inspection on the whole set of modules and will focus on safety aspect too. We conclude that, after 35 years of operation in a temperate climate, approximately 60% (similar to 70% if considering a +/- 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.

  • Details
  • Metrics
Type
research article
DOI
10.1002/pip.3104
Web of Science ID

WOS:000461828200006

Author(s)
Virtuani, Alessandro  
Caccivio, Mauro
Annigoni, Eleonora  
Friesen, Gabi
Chianese, Domenico
Ballif, Christophe  
Sample, Tony
Date Issued

2019-04-01

Publisher

WILEY

Published in
Progress In Photovoltaics
Volume

27

Issue

4

Start page

328

End page

339

Subjects

Energy & Fuels

•

Materials Science, Multidisciplinary

•

Physics, Applied

•

Materials Science

•

Physics

•

crystalline silicon

•

durability

•

long-term performance

•

reliability

•

solar modules

•

wear-out mechanisms

•

degradation

•

exposure

•

modules

•

climate

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
PV-LAB  
Available on Infoscience
June 18, 2019
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/157521
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés