  4. Airflow Characteristics and Pollution Distribution Around a Thermal Manikin--Impact of Specific Personal and Indoor Environmental Factors.
 
research article

Airflow Characteristics and Pollution Distribution Around a Thermal Manikin--Impact of Specific Personal and Indoor Environmental Factors.

Licina, Dusan
•
Melikov, Arsen
•
Kwok, Wai Tham
Show more
2016
ASHRAE Transactions

This study presents a summary of experimental measurements on the airflow characteristics and pollution distribution around a non-breathing thermal manikin. The two objectives are: (1) to examine the extent to which personal (body posture, clothing insulation, table positioning) and environmental factors (room air temperature and ventilation flow) affect the airflow characteristic (velocity and temperature) around the thermal manikin and (2) to examine the pollution distribution within the convective boundary layer (CBL) around a thermal manikin and personal exposure to two types of airborne pollutants under factors that influence theCBL.Theresultsshowthat the CBL generated by the thermal manikin influenced the airflow characteristics and pollution distribution in the breathing zone. Parameters such as room air temperature, body posture, clothing insulation, table positioning, and ventilation flow considerably affected airflow characteristics and pollution distribution around the thermal manikin. Under the specific set of conditions studied, the most favorable airflow patterns in preventing the feet pollution from reaching the breathing zone was transverse flow from the front, as it minimized the exposure at the minimum supply air velocity. Certain airflow directions exhibited a nonlinear dependence between the supply air flow rate and personal exposure. This suggests that without a better understanding of the airflow patterns in a room, the ventilation rate may therefore be increased in vain.

  • Details
  • Metrics
Type
research article
Author(s)
Licina, Dusan
Melikov, Arsen
Kwok, Wai Tham
Sekhar, Chandri
Date Issued

2016

Published in
ASHRAE Transactions
Volume

122

Issue

1

Start page

366

End page

379

Editorial or Peer reviewed

REVIEWED

Written at

OTHER

EPFL units
HOBEL  
Available on Infoscience
July 3, 2018
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/147083
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés