Experimental investigation of the human convective boundary layer in a quiescent indoor environment

Licina, Dusan
•
Pantelic, Jovan
•
Melikov, Arsen
Show more
2014
Building and Environment

This study aims to characterize human convective boundary layer (CBL) in a quiescent indoor environment. The study has two objectives: first, to characterize the velocity field around the thermal manikin under two ambient temperatures and body postures; and secondly, the influence of clothing insulation/design, chair design, table positioning and seated body inclination on airflow characteristics in the breathing zone of a sitting manikin is examined. The increase of the ambient temperature from 20 to 26 °C widens the CBL flow in front of the sitting manikin but do not influence the shape of the CBL in front of the standing manikin. The same temperature increase causes the reduction of the CBL mean peak velocity from 0.24 to 0.16 m/s in front of the sitting manikin. Dressing the nude manikin with thin-tight clothing ensemble reduces the peak velocity in the breathing zone from 0.205 m/s by 17%, and by 40% for thick-loose ensemble. Removing the wig increases the peak velocity from 0.17 to 0.187 m/s. Clothing and chair design have a minor influence on the velocity profile beyond 5 cm distance from the body. Closing the gap between the table and the manikin reduces the peak velocity from 0.17 to 0.111 m/s. Manikin leaned backwards induces the peak velocity of 0.185 m/s, which is 45% above the case when manikin is leaned forward. PIV measurements complemented with Pseudo color visualization (PCV) technique provide a good synergy between quantitative and qualitative airflow characteristics and can be adequately employed for the CBL investigation.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.buildenv.2014.01.016
Author(s)
Licina, Dusan
Pantelic, Jovan
Melikov, Arsen
Sekhar, Chandra
Tham, Kwok Wai
Date Issued

2014

Published in
Building and Environment
Volume

75

Start page

79

End page

91

Editorial or Peer reviewed

REVIEWED

Written at

OTHER

EPFL units
HOBEL  
Available on Infoscience
July 3, 2018
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/147067
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés