000229259 001__ 229259
000229259 005__ 20190317000740.0
000229259 0247_ $$2doi$$a10.1109/IWASI.2017.7974261
000229259 037__ $$aCONF
000229259 245__ $$aAn electrochemical sensor for quantitative analysis of Rhesus D antibodies in blood
000229259 269__ $$a2017-06-15
000229259 260__ $$aVieste, Italy$$bIEEE$$c2017-06-15
000229259 336__ $$aConference Papers
000229259 500__ $$aERC Cybercare 669354
000229259 520__ $$aThe Hemolytic Disease of the Fetus and Newborn (HDFN), if untreated, can have severe consequences on baby’s health, eventually causing death. Prevention and diagnosis of pregnancies at risk of HDFN consists in quantitative analysis in hospital every 2-4 weeks of blood group antibodies in maternal serum. The most important antibodies to be monitored are anti- Rhesus D (or anti-RhD) ones. Nowadays several portable systems for different healthcare applications have been developed towards decentralization of diagnosis thanks to the enormous advances in electrochemical biosensing. Home-monitoring of pregnancies at risk of HDFN could significantly improve patients’ life quality. Here we demonstrate for the first time label-free quantitative detection of anti-RhD antibodies by means of electrochemical impedance spectroscopy (EIS), suitable for integration within a complete portable device. The specificity of the sensor was also proved.
000229259 6531_ $$aHemolytic disease of the fetus and newborn
000229259 6531_ $$aHDFN
000229259 6531_ $$aRh disease
000229259 6531_ $$aelectrochemical sensors
000229259 6531_ $$aelectrochemical impedance spectroscopy
000229259 6531_ $$ablood typing
000229259 700__ $$g267921$$aCriscuolo, Francesca$$0249992
000229259 700__ $$g198935$$aTaurino, Irene$$0245317
000229259 700__ $$g266449$$aKilic, Tugba$$0249688
000229259 700__ $$g182237$$aCarrara, Sandro$$0242413
000229259 700__ $$g167918$$aDe Micheli, Giovanni$$0240269
000229259 7112_ $$dJune 15-16, 2017$$cVieste, Italy$$a7th IEEE International Workshop on Advances in Sensors and Interfaces (IWASI)
000229259 773__ $$tProceedings of the 7th IEEE International Workshop on Advances in Sensors and Interfaces (IWASI)
000229259 8560_ $$fcarole.burget@epfl.ch
000229259 8564_ $$uhttps://infoscience.epfl.ch/record/229259/files/IWASI.pdf$$zn/a$$s656065$$yn/a
000229259 909C0 $$xU11140$$0252283$$pLSI1
000229259 909CO $$pIC$$ooai:infoscience.tind.io:229259$$qGLOBAL_SET$$pconf$$pSTI
000229259 917Z8 $$x112915
000229259 937__ $$aEPFL-CONF-229259
000229259 973__ $$rREVIEWED$$aEPFL
000229259 980__ $$aCONF