  4. Determination of the radiance of cylindrical light diffusers: design of a one-axis charge-coupled device camera-based goniometer setup
 
research article

Determination of the radiance of cylindrical light diffusers: design of a one-axis charge-coupled device camera-based goniometer setup

Pitzschke, Andreas
•
Bertholet, Jenny
•
Lovisa, Blaise
Show more
2017
Journal of Biomedical Optics (JBO)

A one-axis charge-coupled device camera-based goniometer setup was developed to measure the three-dimensional radiance profile ( longitudinal, azimuthal, and polar) of cylindrical light diffusers in air and water. An algorithm was programmed to project the two-dimensional camera data onto the diffuser coordinates. The optical system was designed to achieve a spatial resolution on the diffuser surface in the submillimeter range. The detection threshold of the detector was well below the values of measured radiance. The radiance profiles of an exemplary cylindrical diffuser measured in air showed local deviations in radiance below 10% for wavelengths at 635 and 671 nm. At 808 nm, deviations in radiance became larger, up to 45%, most probable due to the manufacturing process of the diffuser. Radiance profiles measured in water were less Lambertian than in air due to the refractive index matching privileging the radial decoupling of photons from the optical fiber. (C) 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)

  • Details
  • Metrics
Type
research article
DOI
10.1117/1.Jbo.22.3.035004
Web of Science ID

WOS:000397944900009

Author(s)
Pitzschke, Andreas
Bertholet, Jenny
Lovisa, Blaise
Zellweger, Matthieu
Wagnieres, Georges  
Date Issued

2017

Publisher

SPIE Society of Photo-optical Instrumentation Engineers

Published in
Journal of Biomedical Optics (JBO)
Volume

22

Issue

3

Article Number

035004

Subjects

radiance

•

cylindrical light diffuser

•

photodynamic therapy

•

emission profile

•

optical radiation measurement

•

video camera

•

imaging

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
GPM  
Available on Infoscience
May 1, 2017
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/136891
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés