  4. Evaluation of knee functional calibration with and without the effect of soft tissue artefact
 
research article

Evaluation of knee functional calibration with and without the effect of soft tissue artefact

Sangeux, Morgan
•
Barré, Arnaud
•
Aminian, Kamiar  
2017
Journal Of Biomechanics

Functional calibration methods were devised to improve repeatability and accuracy of the knee flexion-extension axis, which is used to define the medio-lateral axis of the femur coordinate system in gait analysis. Repeatability of functional calibration methods has been studied extensively in healthy individuals, but not accuracy in the absence of a benchmark knee axis. We captured bi-plane fluoroscopy data of the knee joint in 17 subjects with unilateral total knee arthroplasty during treadmill walking. The prosthesis provided a benchmark knee axis to evaluate the functional calibration methods. Stereo-photogrammetry data of thigh and shank marker clusters were captured simultaneously to investigate the effect of soft tissue artefact (STA). Three methods were tested, the Axis Transformation Technique (ATT) finds the best single fixed axis of rotation, 2DofKnee finds the axis that minimises knee varus-valgus and trajAJC finds the axis perpendicular to the trajectory, in the transverse plane of the femur, of a point located on the longitudinal axis of the tibia. Using fluoroscopy data, functional axes formed an angle of less than 2° in the transverse plane with the benchmark axis. True internal-external range of movement was correlated with decreased accuracy for ATT, while varus-valgus range of movement was correlated with decreased accuracy for 2DofKnee and trajAJC. STA had negative impact on accuracy and variability. Using stereo-photogrammetry data, the accuracy of 2DofKnee was 1.7°(SD: 5.1°), smaller than ATT 2.9°(SD: 5.1°) but not to trajAJC 1.7°(SD: 5.2°). Our results confirm that of previous studies, which utilised the femur condylar axis as reference.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.jbiomech.2016.10.049
Web of Science ID

WOS:000413886900008

Author(s)
Sangeux, Morgan
Barré, Arnaud
Aminian, Kamiar  
Date Issued

2017

Publisher

Elsevier

Published in
Journal Of Biomechanics
Volume

62

Start page

53

End page

59

Subjects

Soft tissue artefact

•

Functional calibration

•

Knee

•

Total knee arthroplasty

Editorial or Peer reviewed

REVIEWED

Written at

OTHER

EPFL units
LMAM  
Available on Infoscience
January 29, 2017
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/134040
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés