  4. Analysis of lightning electromagnetic field propagation in mountainous terrain and its effects on ToA-based lightning location systems
 
research article

Analysis of lightning electromagnetic field propagation in mountainous terrain and its effects on ToA-based lightning location systems

Li, Dongshuai
•
Azadifar, Mohammad  
•
Rachidi, Farhad  
Show more
2016
Journal of Geophysical Research: Atmospheres

In this paper, we analyze the propagation effects on lightning-radiated electromagnetic fields over mountainous terrain by using a three-dimensional (3-D) finite difference time domain (FDTD) method. We also discuss the time delay error in the time-of-arrival (ToA) technique currently used to locate lightning in detection networks, specifically. Furthermore, the accuracy of different approximate methods presented in the literature is discussed and tested by using our 3-D FDTD method. It is found that (1) the time delays and amplitudes of the lightning-radiated electromagnetic fields can be significantly affected by the presence of a mountainous terrain and associated diffraction phenomena; (2) for a finitely conducting ground, the time delay shows a slight increase with the increase of the observation distance, but the time delay resulting from the finite ground conductivity appears to be smaller than that caused by the mountainous terrain; and (3) the timing error associated with the ToA technique depends on the threshold times. Threshold times of 10% and 20% of the peak provide very similar results compared to those corresponding to the peak of the first derivative of the magnetic field, and the threshold time exceeds 50% of the initial rising amplitude of the signal. Furthermore, we have assessed the accuracy of two simplified methods (terrain-envelope method and tight-terrain fit method) to account for the time delays resulting from the propagation in a mountainous terrain. It is found that both methods result in time delays that are in reasonable agreement but always overestimating the results obtained using the full-wave 3-D FDTD approach for the perfectly conducting ground. These two methods represent interesting alternatives to account for the time delay over a nonflat terrain using the terrain model.

  • Details
  • Metrics
Type
research article
DOI
10.1002/2015JD024234
Web of Science ID

WOS:000370471800020

Author(s)
Li, Dongshuai
Azadifar, Mohammad  
Rachidi, Farhad  
Rubinstein, Marcos
Diendorfer, Gerhard
Sheshyekani, Keyhan
Zhang, Qilin
Wang, Zhenhui
Date Issued

2016

Publisher

Amer Geophysical Union

Published in
Journal of Geophysical Research: Atmospheres
Volume

121

Issue

2

Start page

895

End page

911

Subjects

three-dimensional (3-D) finite difference time domain (FDTD)

•

lightning location system

•

mountainous terrain

•

time of arrival

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
SCI-STI-FR  
Available on Infoscience
February 22, 2016
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/124352
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés