Generating Mobile Fluidic Traps for Selective Three-Dimensional Transport of Microobjects
We demonstrate noncontact transport of microscale objects in liquid environments using untethered, magnetic microrobots. The flow and vortices generated by the rotating microrobot are efficient for selective and gentle trapping, stable transport, and targeted delivery of microscale cargo. The motion of the microrobots can be precisely controlled even at very low frequencies using an advanced magnetic control signal. The design and control methodology presented here can be followed to develop microrobots utilizing the generated fluid flows and performing a variety of biomedical manipulation tasks.
Type
research article
Authors
Publication date
2014
Publisher
Published in
Volume
105
Article Number
114102
Peer reviewed
REVIEWED
EPFL units
Available on Infoscience
February 16, 2016
Use this identifier to reference this record