Estimating the geothermal potential of heat exchanger anchors on a cut and cover tunnel

This study addresses the geothermal potential of using the anchors of a cut-and-cover tunnel as heat exchangers with the ground for seasonal heat storage. The influence of the soil properties and water table level were investigated. Various service conditions were examined, optimised and compared using finite-element analyses. The extractable heat from the ground through the anchors, per year and per kilometre of tunnel, ranges from 0.4 GWh to 0.8 GWh. The seasonal heat storage is shown to be an important factor for the efficiency and sustainability of the heat source.


Publié dans:
Geothermics, 51, 380-387
Année
2014
Publisher:
Oxford, Elsevier
ISSN:
0375-6505
Mots-clefs:
Laboratoires:


Note: Le statut de ce fichier est: Seulement EPFL


 Notice créée le 2014-02-20, modifiée le 2019-03-16

n/a:
Télécharger le document
PDF

Évaluer ce document:

Rate this document:
1
2
3
 
(Pas encore évalué)