  4. Process Control For Ozonation Systems: A Novel Real-Time Approach
 
research article

Process Control For Ozonation Systems: A Novel Real-Time Approach

Kaiser, Hans-Peter
•
Koester, Oliver
•
Gresch, Markus
Show more
2013
Ozone-Science & Engineering

For real-time control of ozonation processes in water works, a sequencing batch reactor was constructed to measure the ozone decay rate constant (k(O3)) in short time intervals of about 15 min. The batch reactor is filled during the production process, immediately after dissolving ozone in water by a static mixer. On the basis of k(O3) and the initial ozone concentration (O-3), and the experimentally determined ratio of the concentrations of (OH)-O-center dot radicals to ozone (R-ct), the degradation of micropollutants in ozone reactors (modeled as Continuously Stirred Tank Reactors - CSTRs) were calculated for compounds with known reaction rate constants with ozone and (OH)-O-center dot radicals. Calculated degradation of atrazine, iopromide, benzotriazole and acesulfame are in good agreement with measured data. For acesulfame the following rate constants were determined in this study at 20 C-o: reaction rate constant with ozone = 88 M(1)s(1), reaction rate constant with (OH)-O-center dot radical = 4.55x10(9) M(1)s(1). For the ozone reaction an activation energy of 35 kJ/mol was determined. Similarly to micropollutants, the relative inactivation of microorganisms (N/N-0) can be calculated based on the inactivation rate constant for ozone and if applicable the lag phase. The pI-value (=logN/N-0) was introduced and implemented in the process management system to calculate online the log inactivation of reference microorganisms such as B. subtilis spores. The system was tested for variation of pH (6.58.5), DOC (1.24.2 mg/L) flowrate 3.212 m(3)/h and temperature (5.79 C-o). Furthermore, a given pI-value, e.g. 1 for a 1-log inactivation of B. subtilis spores, can be set as control parameter in the process management system. The ozone gas flow is then adjusted until the set pI-value is reached. The process control concept was validated with B. subtilis spores. Generally, a good agreement was found between calculated and measured inactivation data. It was also demonstrated, that a constant ozone residual may lead to insufficient disinfection or overdosing of ozone. The new process control concept for ozonations based on onsite measurement of the ozone decay rate constant and the pI-value allows to assess disinfection and degradation processes quantitatively in real-time.

  • Details
  • Metrics
Type
research article
DOI
10.1080/01919512.2013.772007
Web of Science ID

WOS:000317951600003

Author(s)
Kaiser, Hans-Peter
Koester, Oliver
Gresch, Markus
Perisset, Philipp M. J.
Jaeggi, Pascal
Salhi, Elisabeth
Von Gunten, Urs  
Date Issued

2013

Publisher

Taylor & Francis

Published in
Ozone-Science & Engineering
Volume

35

Issue

3

Start page

168

End page

185

Subjects

Ozone

•

Second-Order Rate Constants

•

Acesulfame

•

Ozone Decay Rate Constant

•

Degradation of Micropollutants

•

Disinfection

•

Bacillus Subtilis Spores

•

Reactor Hydraulics

•

Process Management System

•

Process Control

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LTQE  
Available on Infoscience
October 1, 2013
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/95455
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés