Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Validation of 24-hour ambulatory gait assessment in Parkinson's disease with simultaneous video observation
 
research article

Validation of 24-hour ambulatory gait assessment in Parkinson's disease with simultaneous video observation

Moore, Steven T.
•
Dilda, Valentina
•
Hakim, Bandar
Show more
2011
BioMedical Engineering OnLine

Background: Parkinson's disease (PD) is a neurodegenerative disorder resulting in motor disturbances that can impact normal gait. Although PD initially responds well to pharmacological treatment, as the disease progresses efficacy often fluctuates over the course of the day, and clinical management would benefit from long-term objective measures of gait. We have previously described a small device worn on the shank that uses acceleration and angular velocity sensors to calculate stride length and identify freezing of gait in PD patients. In this study we extend validation of the gait monitor to 24-h using simultaneous video observation of PD patients.Methods: A sleep laboratory was adapted to perform 24-hr video monitoring of patients while wearing the device. Continuous video monitoring of a sleep lab, hallway, kitchen and conference room was performed using a 4-camera security system and recorded to hard disk. Subjects (3) wore the gait monitor on the left shank (just above the ankle) for a 24-h period beginning around 5 pm in the evening. Accuracy of stride length measures were assessed at the beginning and end of the 24-h epoch. Two independent observers rated the video logs to identify when subjects were walking or lying down.Results: The mean error in stride length at the start of recording was 0.05 m (SD 0) and at the conclusion of the 24 h epoch was 0.06 m (SD 0.026). There was full agreement between observer coding of the video logs and the output from the gait monitor software; that is, for every video observation of the subject walking there was a corresponding pulse in the monitor data that indicated gait.Conclusions: The accuracy of ambulatory stride length measurement was maintained over the 24-h period, and there was 100% agreement between the autonomous detection of locomotion by the gait monitor and video observation. © 2011 Moore et al; licensee BioMed Central Ltd.

  • Details
  • Metrics
Type
research article
DOI
10.1186/1475-925X-10-82
Author(s)
Moore, Steven T.
Dilda, Valentina
Hakim, Bandar
Macdougall, Hamish G.
Date Issued

2011

Publisher

BioMed Central

Published in
BioMedical Engineering OnLine
Volume

10

Issue

1

Start page

82

Editorial or Peer reviewed

NON-REVIEWED

Written at

EPFL

EPFL units
IMT  
Available on Infoscience
February 24, 2013
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/89113
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés