A multi-center study: Intra-scan and inter-scan variability of Diffusion Spectrum Imaging

Lemkaddem, Alia  
•
Daducci, Alessandro  
•
Vulliemoz, Serge  
Show more
2012
Neuroimage

The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners. (C) 2012 Elsevier Inc. All rights reserved.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.neuroimage.2012.04.045
Web of Science ID

WOS:000305859300010

Author(s)
Lemkaddem, Alia  
•
Daducci, Alessandro  
•
Vulliemoz, Serge  
•
O'Brien, Kieran  
•
Lazeyras, François  
•
Hauf, Martinus
•
Wiest, Roland
•
Seeck, Margitta
•
Krüger, Gunnar  
•
Thiran, Jean-Philippe  
Date Issued

2012

Publisher

Elsevier

Published in
Neuroimage
Volume

62

Issue

1

Start page

87

End page

94

Subjects

LTS5

•

Diffusion MRI

•

DSI

Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LTS5  
Available on Infoscience
March 26, 2012
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/79056
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés