Ambulatory measurement of ankle kinetics for clinical applications

Rouhani, H.  
•
Favre, J.  
•
Crevoisier, X.
Show more
2011
Journal of Biomechanics

This study aimed to design and validate the measurement of ankle kinetics (force, moment, and power) during consecutive gait cycles and in the field using an ambulatory system. An ambulatory system consisting of plantar pressure insole and inertial sensors (3D gyroscopes and 3D accelerometers) on foot and shank was used. To test this system, 12 patients and 10 healthy elderly subjects wore shoes embedding this system and walked many times across a gait lab including a force-plate surrounded by seven cameras considered as the reference system. Then, the participants walked two 50-meter trials where only the ambulatory system was used. Ankle force components and sagittal moment of ankle measured by ambulatory system showed correlation coefficient (R) and normalized RMS error (NRMSE) of more than 0.94 and less than 13% in comparison with the references system for both patients and healthy subjects. Transverse moment of ankle and ankle power showed R>0.85 and NRMSE<23%. These parameters also showed high repeatability (CMC>0.7). In contrast, the ankle coronal moment of ankle demonstrated high error and lower repeatability. Except for ankle coronal moment, the kinetic features obtained by the ambulatory system could distinguish the patients with ankle osteoarthritis from healthy subjects when measured in 50-meter trials. The proposed ambulatory system can be easily accessible in most clinics and could assess main ankle kinetics quantities with acceptable error and repeatability for clinical evaluations. This system is therefore suggested for field measurement in clinical applications. © 2011 Elsevier Ltd. All rights reserved.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.jbiomech.2011.07.021
Web of Science ID

WOS:000296688300018

Author(s)
Rouhani, H.  
Favre, J.  
Crevoisier, X.
Aminian, K.  
Date Issued

2011

Published in
Journal of Biomechanics
Volume

44

Start page

2712

End page

2718

Subjects

Ankle kinetics

•

Ambulatory measurement

•

Inverse dynamics

•

Inertial sensors

•

Pressure insole

•

Ground Reaction Forces

•

Inverse Dynamics

•

Joint Moments

•

Gait Analysis

•

Pressure Distribution

•

Instrumented Shoes

•

Pathological Gait

•

Measuring Device

•

System

•

Kinematics

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LMAM  
Available on Infoscience
September 29, 2011
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/71196
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés