Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Flow-driven diameter response in rat femoral arteries perfused in vitro
 
research article

Flow-driven diameter response in rat femoral arteries perfused in vitro

Porret, C A
•
Stergiopulos, N  
•
Meister, J J
1998
Annals of biomedical engineering

The effects of flow and flow changes on arterial diameter were investigated in vitro on isolated rat femoral arteries. Segments of femoral arteries were excised, mounted on microcannulas, and perfused with Tyrode's solution (37 degrees C). Perfusion pressure was kept constant at 90 mm Hg. The mean external diameter after equilibration at a transmural pressure of 90 mm Hg was 720 +/- 50 microm (n = 12). Vessels were then constricted with norepinephrine (1 microM in the superfusion solution) to 77% +/- 13% of the resting diameter; acetylcholine was used to check endothelial function. The external diameter was measured continuously using video microscopy. The arteries were subjected to two different types of flow variations: (a) step changes in flow (increase and decrease, n = 6) and (b) low-frequency sinusoidal flow variations (frequencies ranging from 0.002 to 0.1 Hz, n = 11). Flow ranged from 0 to 800 microl/min (shear stress ranging from 0 to 15 dyn/cm2). All measured vessels constricted as flow increased. Flow steps induced exponential-like contractions (flow increase) or relaxations (flow decrease) with mean characteristic time constants 31 +/- 4 and 22 +/- 2 s, respectively. Sinusoidal flow oscillations induced sinusoidal diameter oscillations with a time delay. An increase in the frequency of the flow led to a decrease of both the amplitude of the flow-induced diameter oscillations and the phase shift between flow and diameter. The dynamic diameter response to flow changes could be characterized by a first-order low-pass filter with a time constant of 22 s.

  • Details
  • Metrics
Type
research article
DOI
10.1114/1.99
PubMed ID

9662145

Author(s)
Porret, C A
Stergiopulos, N  
Meister, J J
Date Issued

1998

Published in
Annals of biomedical engineering
Volume

26

Issue

4

Start page

526

End page

33

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LHTC  
Available on Infoscience
December 16, 2010
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/62296
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés